{"product_id":"new-flygt-smartrun-src311-50hp-vfd-pump-controller-200-240v-3ph-xylem-wastewater","title":"NEW Flygt SmartRun SRC311 50HP VFD Pump Controller 200-240V 3PH Xylem Wastewater","description":"\u003cp data-start=\"775\" data-end=\"903\"\u003eUp for sale is a \u003cstrong data-start=\"792\" data-end=\"868\"\u003eNEW Flygt SmartRun SRC311 Variable Frequency Drive (VFD) Pump Controller\u003c\/strong\u003e manufactured by \u003cstrong data-start=\"885\" data-end=\"902\"\u003eXylem \/ Flygt\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"905\" data-end=\"951\"\u003eThis unit is brand new surplus and comes with:\u003c\/p\u003e\n\u003cul data-start=\"952\" data-end=\"1043\"\u003e\n\u003cli data-start=\"952\" data-end=\"972\"\u003e\nOriginal packaging\n\u003c\/li\u003e\n\u003cli data-start=\"973\" data-end=\"1004\"\u003e\nFactory manuals\/documentation\n\u003c\/li\u003e\n\u003cli data-start=\"1005\" data-end=\"1043\"\u003e\nAccessories\/hardware shown in photos\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1045\" data-end=\"1302\"\u003eDesigned specifically for municipal and industrial wastewater pumping applications, the SmartRun system combines intelligent pump control with variable frequency drive technology for improved efficiency and reliability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1304\" data-end=\"1307\"\u003e\n\u003ch1 data-start=\"1309\" data-end=\"1325\"\u003eSpecifications\u003c\/h1\u003e\n\u003cul data-start=\"1327\" data-end=\"1676\"\u003e\n\u003cli data-start=\"1327\" data-end=\"1360\"\u003e\n\u003cstrong data-start=\"1329\" data-end=\"1346\"\u003eManufacturer:\u003c\/strong\u003e Flygt \/ Xylem\n\u003c\/li\u003e\n\u003cli data-start=\"1361\" data-end=\"1393\"\u003e\n\u003cstrong data-start=\"1363\" data-end=\"1373\"\u003eModel:\u003c\/strong\u003e SRC311-6-2-0500H-55\n\u003c\/li\u003e\n\u003cli data-start=\"1394\" data-end=\"1419\"\u003e\n\u003cstrong data-start=\"1396\" data-end=\"1412\"\u003ePart Number:\u003c\/strong\u003e 838461\n\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1454\"\u003e\n\u003cstrong data-start=\"1422\" data-end=\"1440\"\u003eInput Voltage:\u003c\/strong\u003e 200–240V ±10%\n\u003c\/li\u003e\n\u003cli data-start=\"1455\" data-end=\"1475\"\u003e\n\u003cstrong data-start=\"1457\" data-end=\"1467\"\u003ePhase:\u003c\/strong\u003e 3 Phase\n\u003c\/li\u003e\n\u003cli data-start=\"1476\" data-end=\"1501\"\u003e\n\u003cstrong data-start=\"1478\" data-end=\"1492\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\n\u003c\/li\u003e\n\u003cli data-start=\"1502\" data-end=\"1527\"\u003e\n\u003cstrong data-start=\"1504\" data-end=\"1522\"\u003eRated Current:\u003c\/strong\u003e 173A\n\u003c\/li\u003e\n\u003cli data-start=\"1528\" data-end=\"1561\"\u003e\n\u003cstrong data-start=\"1530\" data-end=\"1547\"\u003ePower Rating:\u003c\/strong\u003e 50 HP \/ 37 kW\n\u003c\/li\u003e\n\u003cli data-start=\"1562\" data-end=\"1594\"\u003e\n\u003cstrong data-start=\"1564\" data-end=\"1585\"\u003eOutput Frequency:\u003c\/strong\u003e 0–120 Hz\n\u003c\/li\u003e\n\u003cli data-start=\"1595\" data-end=\"1627\"\u003e\n\u003cstrong data-start=\"1597\" data-end=\"1615\"\u003eSerial Number:\u003c\/strong\u003e 58910002002\n\u003c\/li\u003e\n\u003cli data-start=\"1628\" data-end=\"1676\"\u003e\n\u003cstrong data-start=\"1630\" data-end=\"1642\"\u003eMade in:\u003c\/strong\u003e Sweden \/ Xylem Water Solutions AB\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1678\" data-end=\"1681\"\u003e\n\u003ch1 data-start=\"1683\" data-end=\"1693\"\u003eFeatures\u003c\/h1\u003e\n\u003cul data-start=\"1695\" data-end=\"1990\"\u003e\n\u003cli data-start=\"1695\" data-end=\"1741\"\u003e\nSmartRun intelligent wastewater pump control\n\u003c\/li\u003e\n\u003cli data-start=\"1742\" data-end=\"1771\"\u003e\nIntegrated VFD\/drive system\n\u003c\/li\u003e\n\u003cli data-start=\"1772\" data-end=\"1797\"\u003e\nEnergy-saving operation\n\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1833\"\u003e\nAutomatic pump cleaning functions\n\u003c\/li\u003e\n\u003cli data-start=\"1834\" data-end=\"1858\"\u003e\nSoft start \/ soft stop\n\u003c\/li\u003e\n\u003cli data-start=\"1859\" data-end=\"1883\"\u003e\nLCD operator interface\n\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1909\"\u003e\nHand\/Auto control modes\n\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1956\"\u003e\nDesigned for Flygt N-pumps and lift stations\n\u003c\/li\u003e\n\u003cli data-start=\"1957\" data-end=\"1990\"\u003e\nIndustrial heavy-duty enclosure\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1992\" data-end=\"2177\"\u003eAccording to Xylem, SmartRun controllers are optimized for wastewater pump stations and include adaptive cleaning and energy minimization features. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2179\" data-end=\"2182\"\u003e\n\u003ch1 data-start=\"2184\" data-end=\"2201\"\u003eCondition Notes\u003c\/h1\u003e\n\u003cul data-start=\"2203\" data-end=\"2385\"\u003e\n\u003cli data-start=\"2203\" data-end=\"2216\"\u003e\nNew surplus\n\u003c\/li\u003e\n\u003cli data-start=\"2217\" data-end=\"2234\"\u003e\nNever installed\n\u003c\/li\u003e\n\u003cli data-start=\"2235\" data-end=\"2268\"\u003e\nIncludes original documentation\n\u003c\/li\u003e\n\u003cli data-start=\"2269\" data-end=\"2306\"\u003e\nIncludes packaged accessories shown\n\u003c\/li\u003e\n\u003cli data-start=\"2307\" data-end=\"2323\"\u003e\nStored indoors\n\u003c\/li\u003e\n\u003cli data-start=\"2324\" data-end=\"2385\"\u003e\nMay show minimal shelf\/storage wear from warehouse handling\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2387\" data-end=\"2390\"\u003e\n\u003ch1 data-start=\"2392\" data-end=\"2402\"\u003eShipping\u003c\/h1\u003e\n\u003cul data-start=\"2567\" data-end=\"2650\"\u003e\n\u003cli data-start=\"2404\" data-end=\"2438\"\u003e\nShips freight due to size\/weight\n\u003c\/li\u003e\n\u003cli data-start=\"2439\" data-end=\"2475\"\u003e\nForklift recommended for unloading\n\u003c\/li\u003e\n\u003cli data-start=\"2476\" data-end=\"2500\"\u003e\nLocal pickup available\n\u003c\/li\u003e\n\u003cli data-start=\"2501\" data-end=\"2536\"\u003e\nBuyer may arrange freight carrier\u003c\/li\u003e\n\u003cli data-start=\"2605\" data-end=\"2650\"\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Flygt\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e General Purpose Vector AC Drive\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnit Type:\u003c\/strong\u003e Unit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e 50 HP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e SmartRun SRC311\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e SRC311-6-2-0500H-55\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 200-240V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnit Quantity:\u003c\/strong\u003e 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Sweden\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Flygt","offers":[{"title":"Default Title","offer_id":48343721017562,"sku":"VFD-1","price":2499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0838\/7071\/2026\/files\/10_8b15771d-b89a-4706-8570-93bb78c9bd74.jpg?v=1786713582","url":"https:\/\/lamonsurpluseq.com\/products\/new-flygt-smartrun-src311-50hp-vfd-pump-controller-200-240v-3ph-xylem-wastewater","provider":"Lamon Surplus Equipment","version":"1.0","type":"link"}